Skip to content
Astha Dhami
Internship ProjectUX DesignUX Research

Closing the Gap Between Siemens and ENERGY STAR

Designing a clearer way for sustainability teams to configure how data moves between them, and resolve sync failures without escalating.

Siemens data sync case study cover preview
Siemens data sync case study cover preview.
Role
UX Designer/Researcher
Team
Siemens's Sustainability Energy Management Team aka Big Sus Energy
Tools
Figma, FigJam, Claude
Timeline
8 months
01

Understanding the problem

Mapped the reconciliation gap

02

Designing

Shaped the core flows

03

User testing and feedback

Refined labels and affordances

04

Handoff

Prepared build-ready direction

Sustainability teams were syncing ENERGY STAR data by running SQL commands directly against the internal database, hours of work per client, with room for error at every handoff. I ran competitive analysis, assessed API feasibility, designed wireframes and prototypes, and led usability testing to rebuild the integration from the ground up.

2–3 hours → under 15 minutes

Setup time

100+

Sustainability managers

2

Moderated testing sessions

Solution Overview

Three questions the design had to answer.

01

What is connected?

ESPM landing page showing the sites table with connected site data

Which sites and meters are linked, what permission level applies, and how current the data is.

02

Which direction is data moving?

Utility Account Config screen showing meter sync direction settings

Control over sync configurations at the meter and attribute level.

03

What happens when a sync fails?

Sync Status error state showing a clear failure message and timestamp

Failure details surfaced on hover with a timestamp and a message the team could easily understand.

Context

The same data, maintained twice

Siemens Asset Management Software helps organizations manage buildings, infrastructure, and physical assets from maintenance and work orders through to budgets and long-term planning.

Stream was the enterprise platform I worked on at Siemens, focused on energy and sustainability. It brings utility data like electricity, water, and gas together, so organizations can monitor consumption, track carbon emissions, and make informed decisions across large building portfolios.

Siemens Asset Management Software

Buildings, meters, utility records, and internal services workflows.

PushPull
ENERGY STAR Portfolio Manager

Portfolio records, scores, certifications, and externally owned source data.

A two-system workflow looked simple from far away, but every data type had its own direction, ownership, and failure mode.

When a client with ENERGY STAR data came on board, there was no interface to onboard or sync anything — our internal services team wrote SQL to move records between the two platforms, then cross-referenced both systems to catch whatever had drifted. That manual process was already difficult. It got even more difficult because the sync rules weren't uniform:

ENERGY STAR scores

were only ever pulled in

Utility data

moved one way only

Spaces

could move in both directions

When the two systems disagreed, there was no straightforward way to tell which one was right.

User Research

The biggest finding? The structure.

I asked the team early which product represented the ideal state. The answer was Measurbl, so I created an account and worked through it, tracing four key flows: connecting sites to a new ENERGY STAR account, the sync process, deleting meters, and editing meter information.

Measurbl moves from portfolio to meter through progressive drill-down, each level shows only what's relevant at that depth, and the level below it is one click away.

  1. 01A portfolio-level site list
  2. 02Then site details
  3. 03Then utilities grouped by type
  4. 04Then an individual meter profile
Two things I carried forward from Measurbl

Connection status

Siemens Sites page showing linked account, sync timing, and pending site shares

What's connected is answered before you drill into anything.

Side sheet, not a new page

Meter Profile side sheet open over the Utilities page

Meters open in a side sheet, not a new page.

The competitor analysis also helped the team size the real scope of the problem. This shifted the question from "what to build" to "what to ship first." Working with the product owner, I plotted our capabilities on an impact-versus-effort matrix, and we refined our features and user stories around delivering the highest-impact, lowest-effort work first.

This was the final user flow we decided to target:

User flow: from Integrations > ENERGY STAR > ESPM Config, through the ESPM table and a site row's side sheet, into either meter push/pull settings or attribute sync settings.

Final Designs

The interface makes the invisible state visible.

The final direction gives energy managers a readable overview first, then lets them move into configuration and recovery without losing their place.

Overview, configuration, and recovery are part of one continuous mental model.

User Testing

Turning one constraint into something useful.

For the user testing, we wanted to take feedback from users who were not involved in the earlier discussions, but we realized it would be difficult to get more people from the service team. So, we had to carry out two moderated discovery sessions of 60 minutes each with users from another team.

Two participants are a small pool, and both came from Energy Manager rather than Stream, so neither had much context on the site types the product distinguishes between. I noted that as a constraint, but it turned out to be useful, their unfamiliarity surfaced labeling problems a Stream-native user would have read past.

01

What tested well

Participants understood the sync-direction language and could change how meter data moved between Stream and ESPM. ENERGY STAR Score color also supported quick scanning.

02

What changed

Testing surfaced a lot of small friction points, but three patterns kept showing up across sessions.

ESPM landing page before testing, with an ungrouped sites table and limited status context
Before testing
ESPM landing page after testing, with color-coded scores, clearer labels, and contextual tooltips
After testing

Terminology didn't match how users thought.

Column headers and table labels used internal naming that users found unclear - "Property Data Admin" meant nothing on first read, and users weren't sure what "1/2 site failed" was telling them. We renamed the confusing terms and added tooltips wherever a label needed more context than a header could carry on its own.

Status needed to be scannable, not just readable.

Users understood the ES Score column immediately, but reading each row individually to check status was slow. We added colour-coding to the ES Score cells, so status is visible at a glance instead of requiring a read of every entry.

Knowing when something failed mattered as much as knowing that it failed.

For troubleshooting, users needed to know the timing of an error, not just its existence. We added date and timestamp to the error hover state, so a failure could be traced back to a specific moment rather than just flagged as "something went wrong."

Impact

The work turned a reconciliation task into a product workflow.

2–3 hours → under 15 minutes

Setup time

100+

Sustainability managers across North America

1 view

To see ownership, direction, and sync state together

Teams can see what is connected before they act.

Sync direction is explicit at the level where decisions happen.

Failures become actionable product feedback, not engineering tickets.

Other contributions

Alongside my main project, I reached out to other teams to contribute and learn more during my internship.

1.Design System Alignment with SiemensAudited Stream’s interface against Siemens standards to identify inconsistencies and opportunities for alignment.

When the product moved under Siemens, two design languages needed to speak the same dialect. I audited core UI components, toasts, the top app bar, and tabs, against Siemens design standards, identifying inconsistencies in interaction patterns, visual hierarchy, and component behavior. The audit produced a clear path for bringing the product's component library into alignment with Siemens standards, reducing UI inconsistency across the product suite and laying the groundwork for a more scalable, unified design system.

Siemens design system audit showing Siemens interface components and states
Siemens design system alignment audit.
Explore design systems case study
2.Making User Behavior VisibleBuilt a Pendo dashboard around the team’s questions about usage, engagement, and retention.

Rather than grouping widgets by chart type, I organised them around the product questions people kept asking in meetings — how many customers have this, what are they using, is engagement improving, how long until a new user gets value, are they coming back. Each section opens with its question, and every widget carries a short explanation of how to read it, so the dashboard works for someone who has never opened Pendo.

Reflection

This project sharpened how I design for enterprise complexity without making the interface feel heavy.

What I learned

Enterprise UX is often about deciding what complexity belongs on the surface, what belongs one layer deeper, and what needs clearer system feedback before a user can act confidently.

Technical fluency made the design sharper

Bringing my software engineering background into the feasibility assessment helped me ask better implementation questions early and build credibility with engineering partners.

What I would improve next

If I had more time and resources I would push for another round of testing with fresh participants from the services team to validate the revised row affordance and error-recovery flow, then measure setup completion, time to resolve sync failures, and support dependency after release.

A favorite desk at the Siemens office overlooking city buildings
Kudos message appreciating Astha's first research project
Shout out message recognizing Astha's UX research readout template
Kudos message recognizing Astha's ESPM research and design work
A favorite corner of the Siemens office, and a few notes of appreciation from the team